Pressure sensors measure pressure in comparison to a reference pressure and can be divided into:
Absolute pressure Absolute pressure is referenced to the vacuum of free space (zero pressure).
Vented Gauge pressure: Gauge pressure is measured relative to the ambient atmospheric pressure.
Sealed Gauge pressure: It is possible to seal and block the vent hole in the factory. The advantage of this sealing is that, pressure on back of the sensor will be constant and equal to atmospheric pressure in the manufacturing company. This is a sealed gauge pressure.
Differential pressure: Differential pressure is the difference between any two process pressures p1 and p2.
Please click here for more detailed information
An analogue signal is infinitely continuous; a digital signal is quantised or broken up depending on bit resolution.
This is the process in which an analogue signal is quantised into a digital signal, usually performed by a device known as an analogue to digital converter.
Typically not.
For some multiplexed systems, sampling rate is divided equally among different channels, so please check specifications carefully.
This is the point where the signal will attenuate to about 70.7% of the original signal, usually chosen as a marker in which to describe the bandwidth of a filter or device.
Output impedance is the minimum resistive load on an electrical output that will not cause a voltage drop for a given voltage. Input impedance is the amount of resistive loading in an electrical input.
All MeasureX load cells, pressure transducers and LVDTs with analogue output have infinite resolution. The resolution is limited by the electronics noise that they are used with.
“FS” stands for Full Scale and “RO” stands for Rated Output of the transducer. Most errors are shown as a percentage of FS or RO.
The electrical output of a transducer is often stated in millivolts (mV) per volt (V) of sensor excitation at full range. For example the electrical voltage output of a load cell with 2mV/V output at rated capacity utilizing 10volts excitation will be 20mV at rated load.
MeasureX aims to stay abreast of the latest technologies to bring the best to our customers. The most appropriate technology is used to suit the varied applications we come across. Please check the data sheet of the specific product for more information.
Yes it does and, as a rule of thumb, generally these errors are negligible for a cable length of up to 20m. We do offer 6 wire load cells which help to compensate for the lead resistance and allows much longer cable lengths.
Please check the excitation level in data sheet of each product. MeasureX can customise excitation voltage so please ask our sales department if you have a need for any non-standard excitation voltage.
Generally yes.
Yes, it is available for most models in NPT, BSPT or BSPP. Please specify when you want to place the order.
Please contact Support@MeasureX.com.au for information on how you can convert 4-20mA output to 1-5V or 2-10V using a 250Ω or 500Ω precision resistor.
IP= Ingress Protection; submersible certification -all tests- solids (0-6) and liquids (0-8). Find more information in technical tips. For more information, click here.
We offer several of the most common metric and non-metric scales on many catalogued products at no additional cost. Special scales can be created as per your requirements.
Yes, we customise our product offering all the time.
We can generally help you with this transition. Please contact our sales department with the technical specification of your current sensor. Our engineers will help you to select the best alternative.
MeasureX prefers Electronic Funds Transfer and also accepts Visa and Mastercard. Please contact our accounts department for any further information.
Shipping costs for your order are generally shown in the quotation and invoice we provide for you. Please contact our accounts department for additional details.
Yes, we offer an extended warranty service. Please ask our sales department for more information.
Yes. If you have your own courier, just inform us when you place the order and the shipping cost will be charged to your courier account.
Absolutely! Our experienced regional sales representatives/resellers are ready to help you with all your needs. If there is no representative/reseller for your region, please place your order directly with MeasureX headquarter in Australia.
Yes, we ship our products to all corners of the world.
Every transducer of various brands are affected by changes in temperature. MeasureX tests all its transducers for temperature and specifies the temperature coefficient to give an idea of the change per °C.
There is no set life span for any of our products, as it varies based on usage. For critical applications, the unit should be typically tested annually.
Every MeasureX sensor is thoroughly tested in the factory and a calibration or conformance certificate issued with each sensor supplied. NATA calibration certificate is an optional extra
No problem. MeasureX keeps a backup of this information on all the sensors it manufactures. Please contact us for a copy.
For any technical questions, please contact our sales or technical department (Sales@MeasureX.com.au / Support@MeasureX.com.au)