Contact Us
✖

    • Technical Specification
    • Features
    • Applications
    TechnologyCeramic
    TypePressure Transducer
    Standard Measurement Range (bar)[-1/0], 200
    Purpose and ApplicationGeneral Purpose, Corrosive Media
    Accuracy (combined LRH)0.25% FS, 0.5% FS
    Output Signal2mV/V
    Pressure ReferenceSealed to 1 bar
    Process ConnectionG1/4(¼” BSPP male)
    Electric Connection2m cable
    Protection LevelNo
    Overload Rating150%
    Long Term Stability<0.2% FS/year
    Diaphragm MaterialStainless Steel 316L
    Compensated Temp. Range0 to 70°C
    Operating Temp. Range-10 to +80°C
    Temp. Coefficient of Zero0.02% FS /°C
    Temp. Coefficient of Span0.02% FS /°C
    Input ResistanceNo
    Output ResistanceNo
    Insulation resistance100MΩ @ 50VDC
    Zero offsetNo

    Well priced for OEM applications
    High Measuring Accuracy
    Pressure Measurement Range of -1 to 200bar
    Wide Range of Media Compatibility
    Low Static and Thermal Errors

    Autoclave and other steam sterilizers
    Agricultural chemical spray equipment
    Aggressive fluid tank farms
    Hydraulics
    Sub-sea survey equipment
    Purging lines Industrial washing equipment
    Laboratory analyzers